LB1

LB1P_P51

LB1P_P41

LB1P_13

LB1P_P42

AC-15 SNAP ACTION
Screenshot 2018-10-15 10.46.28
AC-15 SLOW ACTION
Screenshot 2018-10-15 10.46.32
DC-13
SNAP ACTION
SLOW ACTION
Power breaking for a durability of 5 million operating cycles
Voltage 24V
9.5 W
12 W
Voltage 48V
6.8 W
9 W
Voltage 110V
3.6 W
6 W

LB4

LB4P_G42

LB4P_G5100

LB4P_G41

Serie LB4_U / LB4_UP
Serie LB4_M
Serie LB4_A
Screenshot 2018-10-15 18.32.09
Screenshot 2018-10-15 18.32.15
Screenshot 2018-10-15 18.32.19

TECHNICAL SPECIFICATIONS

LB1 SERIES

Standards
IEC 60947-5-1
EN 60947-5-1
Certifications – Approvals
UL-CSA-IMQ-EAC-CCC
Air temperature near the device
– during operation (C°)
– for storage (C°)
-25…+70
-30…+80
Mounting position
All position are authorised
Protection against electrical shocks (acc. toIEC 61140)
Class II
Degree of protection (according toIEC 60529 and EN60529)
IP 65
ELECTRICAL DATA
Rated insulation voltage Ui
– according toIEC 60947-1 andEN60947-1
– according toUL 508 andCSAC22-2 n° 14
500 V (degree of pollution 3)
(400V for contacts type Z6, X7, X8, W9)
A 600, Q 600 (A 300, Q300 for contacts type X12P, X21P, W03P)
Rated impulse withstand voltage Uimp
(according toIEC 60947-1 andEN60947-1) (kV)
6
Conventional free air thermal current Ith
(according toIEC 60947-5-1) 0 < 40 °C (A)
10
Rated operational current
le / AC-15 (according to IEC 60947-5-1)
le / DC-13 (according to IEC 60947-5-1)
24V-50/60Hz (A)
120V-50/60Hz (A)
400V-50/60Hz (A)
24V-50/60Hz (A)
120V-50/60Hz (A)
400V-50/60Hz (A)
10
6
4
6
0.55
0.4
Switching frequency (Cycles/h)
3600
Load factor
0.5
Resistance between contacts (mΩ)
25
Connecting terminals
M3.5 (+,-) pozidriv 2 screw with cable clamp (M3 for 3 poles contacts type)
Terminal for protective conductor
Connecting capacity (1 or 2 x mm2)
0.75 … 2.5 (0.34… 1.5 for 3 poles contacts type)
Terminal marking
According to IEC 60947-5-1
Mechanical durability
15 mlns of operations
10 mlns of operations
>5 mlns of operations
T10…12; T21; T2101; T30… 34; T38
T13; T41…48; T51…55; T61… 75
T14; T35; T36; T39; T91…93; T98
Electrical durability (according to IEC 60947-5-1)
Utilization categories AC-15 andDC-13
(Loadfactor of 0.5 according tocurves below)

LB4 SERIES

Standards
IEC 60947-5-1
EN 60947-5-1
Air temperature near the device
– during operation (C°)
– for storage (C°)
-25…+70
-40…+70
Mounting position
All position are authorised
Protection against electrical shocks (acc. toIEC 61140)
Class II
Degree of protection (according to UL50)
Type 1 enclosure (“indoor use only”)
Switching frequency
3600
Mechanical durability
10 millions of operations
ELECTRICAL DATA
Code
LB4_U
LB4_UP
LB4_HF
LB4_M
LB4_A
Cable type
4xAWG18
PVC style
4xAWG18dynamic
PUR style 20668
4xAWG18 halogen free
PUR style 20668
Min. bend radius
49 mm
49 mm
49 mm
Rated insulation voltage Ui
400V
300V
300V
250V
250V
Rated impulse withstand voltage Uimp
4kV
4kV
4kV
2.5kV
2.5kV
Conventional free air thermal currentith
10A
10A
10A
4A
4A
Short-circuit protection
10A 500V
type gG
10A 500V
type gG
10A 500V
type gG
4A 500V
type gG
4A 500V
type gG
Rated insulation voltage Ui
400V
300V
300V
250V
250V
AC15
24V
120V
240V
10A
6A
3A
10A
6A
3A
10A
6A
3A
4A
3A
3A
4A
3A
3A
AC15
24V
125V
250V
2.8A
0.55A
0.27A
2.8A
0.55A
0.27A
2.8A
0.55A
0.27A
2.8A
0.55A
0.27A
2.8A
0.55A
0.27A
Approvals
cUlus EAC
CCC
cUlus EAC
cUlus EAC
cUlus IMQ
EAC CCC
EAC